Scheme Introduction

SLIQUID GLOBAL Immersion Liquid Cooling Data Center Infrastructure Solutions C8000 is designed to solve the heat dissipation problem of ultra-high density blade servers.

Immersion liquid cooling infrastructure solution uses low boiling point/non-conductive liquid as the refrigerant, all server components are immersed in the refrigerant, and all server components achieve 100% liquid cooling, using the principle of refrigerant boiling heat absorption, to achieve efficient cooling of heating components, providing a stable operating environment for the operation of the server.

Application Scenario

C8000 is mainly used in high density and ultra-high density data center room to meet the scientific computing, artificial intelligence computing and other applications in scientific research, government, medical, education, finance and Internet fields.

Basic Principle of Cold Plate Liquid Cooling

Solution Features

High efficiency heat dissipation
Using a low-boiling-point liquid as a coolant, all electronic components are immersed in the coolant, which directly contacts the heat-generating devices, reducing thermal contact resistance. Through the temperature rise and vaporization of the coolant, it can achieve efficient heat dissipation up to 200W/cm².
High-density Deploy
Within a space of 2600mm in height × 2100mm in width × 1400mm in depth, up to 160 computing nodes of immersion liquid-cooled blade servers can be deployed, with a single cabinet power reaching up to 220kW, saving more than 85% of the data center floor space.
Safe and reliable
Utilizing an insulating, environmentally friendly, non-toxic, and harmless cooling liquid as a coolant, it is non-corrosive to electronic equipment and safe for human use. Even if the coolant used in immersion liquid cooling technology leaks, it poses no risk to computer hardware or the external environment.
Efficient Power Supply
The server adopts DC 400V direct current power supply, reducing the AC/DC conversion process, with a system efficiency of over 96%, meeting the high power consumption supply needs while reducing power distribution losses.
Extreme energy saving
All heat-generating components are 100% equipped with immersion liquid cooling technology, utilizing water at 15~35°C as a cooling source, which can achieve natural cooling throughout the year.
The immersion liquid cooling technology features a fanless design, reducing fan power consumption to zero, and saving more than 30% energy compared to traditional air-cooled data centers.
Continuous and Stable
Using liquid cooling technology reduces the operating temperature of components, minimizes the temperature variation range of the components, enhances the reliability of the components, and ensures an even internal temperature field, avoiding local hot spots in the equipment.
Higher performance
The temperature of main electronic components such as the CPU is reduced, and the amplitude of load fluctuations is decreased, which can fully tap into the potential of the chip and enhance the overall performance of the computer system.
Rich in a sense of technology
The immersion liquid cooling infrastructure has an appearance full of technological feel. The server cabinets and servers can have transparent display windows, allowing the external observation of the boiling scene inside the servers, which has a very good display effect.

Product Features

High Performance

Ultimate Energy Saving

High-Density Deployment

Safe and Reliable

inquiry @slgdc.com
移动端浏览
通过手机继续浏览
返回顶部