Scheme Introduction
SLIQUID GLOBAL air-cooled data center, Smart pool-level micro-module solution C2000 provides customers with safe, fast, green and intelligent data center solutions. The C2000 adopts the ultra-high standard modular design concept. It integrates the cabinet, closed hot and cold aisles, power distribution, cooling, and monitoring systems into an integrated micro-module in the equipment room, enabling quick installation, on-demand deployment, and secure and reliable delivery. Combined with the intelligent integrated management platform, it improves the security and energy saving of the system, realizes the linkage control between various systems, and provides facilities monitoring, asset management, capacity management, energy efficiency management and other functions to effectively improve the resource utilization and operation and maintenance efficiency of the data center.
Solution Features
- Safe and Reliable
- The key devices in the system are redundant to ensure the running environment of IT devices
- The monitoring system monitors temperature, humidity, smoke, water and other environmental parameters in the system in real time, as well as the operation of power supply and distribution, air conditioning and other equipment, and sends alarm signals when the system is abnormal.
- The internal equipment of the system has linkage control function, when the fire occurs, the roof of the channel will automatically open, and the sound and light alarm will be issued;
- The structure design is reasonable and meets the seismic intensity of 8 and 9.
- Fast and Convenient
- The modular design makes the installation or expansion of the Data Center Room very fast and convenient
- The Data Center Room has low requirements on the construction site, and can support direct installation on the ground, and the installation height is only 2.7 meters
- Reduce the amount of Data Center Room construction, and shorten the construction period by 30%-50%
- Green and low-carbon
- Utilizing aisle-based air conditioning for close-proximity cooling significantly enhances the efficiency of cold air delivery.
- Employing aisle-enclosure technology completely separates the cold and hot air within the data center, preventing air mixing and increasing the temperature of the air conditioning return air, which effectively boosts the efficiency of the cooling system.
- The air conditioning system features a full-variable frequency design, with the option for high-efficiency energy-saving modules, further improving the system's energy conservation capabilities.
- The high-efficiency power supply and distribution system achieves an overall efficiency of up to 96%.
- The intelligent micro-module solution for data center facilities has an average annual PUE value ranging from 1.15 to 1.3.
- Intelligent and Efficient
- The monitoring system monitors temperature, humidity, smoke, water and other environmental parameters in the system, as well as the operation of power supply and distribution, air conditioning and other equipment, and sends an alarm when abnormal;
- Provide facilities monitoring, asset management, capacity management, performance management and other functions;
- Provide a variety of standard communication protocols, can integrate security, video, fire and other systems; With the ability to upload data, remote management;
- Multi-device linkage function can be customized to realize automatic system operation and optimization;
Support robot inspection, intelligent operation, unattended.
Application Scenario
C2000 is mainly used in large, medium, and small-sized medium - and low-density data centers
Simple and elegant design, friendly building compatibility, to meet the financial, government, operators, science and education, medical and other industries of the data center needs.
It is suitable for new construction and renovation of data center projects, which can meet various construction needs such as energy saving and emission reduction, space limitation, phased delivery, beautiful and generous.
Technical Specification Sheet
(Length, Width and Height)
L×2300×2300mm,L≤15m;L×2400×2300mm,L≤15m;
Dual-row sealed cold/hot aisle (length width height) (width does not include the thickness of the outer cabinet door)
L×3400×2300mm,L≤15m;L×3600×2300mm,L≤15m;