Product Introduction
Liquid Cooling Energy-Saving Precision Fan Wall CRAC are a form of data center precision air conditioning, undertaking the main task of temperature and humidity control in the data center room. They keep the environmental temperature and humidity of the data center room continuously within a reasonable range to meet the usage requirements of IT equipment. With a wind wall structure and advanced liquid cooling technology, they are designed for large-scale liquid cooling data center infrastructure and operating environments, offering advantages such as more flexible control, lower cost, and higher energy efficiency.
Application Scenarios c
Medium to large-scale liquid-cooled data centers, industrial precision control rooms, switching rooms, and modular data centers.
Product Advantages
- Highly Integrated
- The system is highly integrated design, the compressor, condenser and evaporator are highly integrated in the same frame, and the structure is more compact; Two refrigeration systems are integrated in the same unit with three operating modes.
- Energy-Efficient
- The air conditioner is highly integrated with three operating modes, which automatically switch based on ambient temperature, making the most of outdoor natural cold sources;
- The fan array is arranged in a horizontal air delivery pattern, with a large air outlet design, providing a broader cold air coverage area, more uniform air delivery, and higher fan efficiency;
- The mechanical refrigeration adopts a water-cooled direct expansion mode, which is more energy-efficient and quieter compared to the traditional air-cooled mode.
- Intelligent Control
- The air conditioner's intelligent control system can monitor and analyze in real time based on environmental conditions, indoor and outdoor temperatures, human activities, and other factors, and make optimized dynamic adjustments through intelligent algorithms;
- The intelligent control system of the air conditioner has automated management capabilities, enabling remote monitoring and control. Users can monitor, adjust, and manage the air conditioning equipment anytime, anywhere, which is convenient and efficient.
- The system achieves abnormal alarms and automatic maintenance through data analysis and fault diagnosis functions, enhancing the reliability and operational efficiency of the equipment.
Technical Specification Sheet
Types | Name/Unit | CIF-150D |
---|---|---|
Performance Parameters | Total Cooling Capacity(kW) | 150 |
Sensible Heat Ratio | ≥95% | |
Water Flow Rate(m³/h) | 36 | |
Water Side Pressure Drop(kPa) | ≤150 | |
Pressure Resistance(Mpa) | 1.6 | |
No. of Compressors(PCS) | 2 | |
Airflow(m³/h) | 37000 | |
Numbe of Fans(PCS) | 9 | |
Heating Capacity(kW) | 15 | |
Humidifying Capacity(kg/h) | 8 | |
Pipe Connection Specifications | Refrigerant Gas Pipe Specifications(mm) | 22 |
Refrigerant Liquid Pipe Specifications(mm | 19 | |
Inlet and Outlet Water Pipe Connection Sizes | DN80 | |
Inlet and Outlet Pipe Connection ways | Chuck Connection″ | |
Humidity Humidifier Inlet Interface | OD10(Tower Type Connector) | |
Drain Pipe Diameter(mm) | ID16╳OD24 | |
Electrical Parameters | Power Supply Specifications | 380VAC/3ph/50HZ |
Max Current¹ (A) | 95 | |
Recommended Power Cord Specifications(mm2) | 5×25 | |
Recommended Circuit Breaker Specifications for Indoor Units(A) | 125 | |
Dimensions Width×Height×Depth |
Width×Depth×Height(mm) | 2400×1300×2400 |
Weight (kg) | 1400 |
*Note:
1. ①These parameters are for the configuration under constant temperature and humidity conditions;
2. Operating conditions: Indoor at 37℃/24%RH, outdoor at 35℃. If you have any other requirements, please contact our company.