Scheme Introduction

SLIQUID GLOBAL air-cooled Micro Data Center Infrastructure Solutions C500, designed according to data center room standards.

The design concept of an integrated rack is adopted. The rack is used as the computer environment carrier.

It consists of rack, cooling module, power distribution module, monitoring module, UPS module, battery pack,and server rack to form a rack-level "micro" data center. The product is composed of a comprehensive control rack and a server rack. It has the features of security, stability, easy deployment, high integration, noise and dust reduction, energy saving and high efficiency, intelligent and worry saving, etc., and is widely used in the monitoring industry, medical industry, radio and television industry, communication industry and financial industry.

Solution Features

Security and Stability
Each system has a high degree of matching, and each system contains intelligent communication interfaces, which can observe the running status from the monitoring screen and remote access interface;
The rack provides functions such as high temperature, fire control linkage, and emergency skylight heat dissipation to ensure the secure and stable running of IT devices.
Easy to Expand Capacity
Using modular design, functional modules can be combined on demand to meet the needs of different users.
odularity makes system expansion more convenient and fast.
Only need to upgrade or replace function modules to expand capacity.
Easy to Deploy
All the devices in the rack are mounted in a rack, and are coordinated and initialized before delivery
There is no need to use tools to put on the shelf, and it can be used normally after starting.
The air conditioning system does not require on-site welding installation and maintenance, reducing the complexity of on-site operation, and the integrated structure saves the floor space.
Highly Integrated
Single rack integrates power distribution, cooling, monitoring and other functions, fewer and more centralized devices, more stable operation, lower failure rate and maintenance costs, compact structure, providing more equipment installation space.
Energy-saving and Efficient
A high-efficiency modular UPS is installed in the rack for higher power supply efficiency. The refrigeration module adopts high efficiency and low noise DC frequency conversion compressor and EC fan; Energy saving and noise reduction, beautiful effect. The PUE is lower.
Smart and Easy
Independent control, adjustment, automatic control, adjustment of air flow, air volume in the rack, integrated temperature, humidity, smoke sensing, water leakage detection system.
Remote monitoring and intelligent humanized management, can be achieved without staff on-site duty.

Application Scenario

Finance, Education, Communication, Government, Medical care, Transportation, Energy, Small and Medium-sized Enterprises, Commercial outlets, etc.,C500 can be deployed without a computer room.

Technical Specification Sheet

System Parameter
Dimensions (Length, Width and Height)
L×1200×2000mm,L≤6m; (Single Integrated rack)
Number of IT racks per Module
Number of IT racks per Module 0~9
Type of Aisles
Single Row Layout, Closed Hot and Cold Aisles
IT Load per rack
No more than 7kW is recommended
Type of Power Supply
Type of Power Supply 220/380/400/415,50/60HZ
Rack System
Working Environment
-40℃~45℃ (When the temperature is lower than -15 ° C, low-temperature components will be selected)
Cable routing
Top/Bottom In-line, Top/Bottom Out-line
Mounting Method
Surface-Mounted/Suspended Floor-Mounted
Temperature Control System
Dimensions
2000×600×1200mm
Available space
42U
Rack Load-Bearing Capacity
Static Load 2000kg
Cooling Capacity
6.5kW/7.5kW/12.5kW
Mounting Type
Rack-Mounted Installation
Power Supply and Distribution System
Airflow Configuration
Front Air Supply, Rear Air Return
Mounting Type
Rack-Mounted Installation
Lightning Protection Class
C-Level Lightning Arrestor (In=20kA)
Power Input
Single Power Input, Dual Power Input is Optional
UPS Capacity
6kVA/10kVA/15kVA/20kVA/30kVA/40kVA/60kVA
Maintenance Bypass
Standard Configuration
Battery
Rack-Mounted Battery Pack/Battery rack
PDU
Supports IEC or National Standard Outlets
Monitoring System
Monitoring System
Supports remote access and centralized monitoring of multiple sites
Local Interface
10-inch Touchscreen
Standard Configuration
Temperature and humidity monitoring, Smoke detection, Air conditioning, UPS, Power distribution operation data display, and Fault alarms.
Fire Protection System
Optional function
Water leakage, Sound and Light Alarm, Electronic Lock, SMS Alarm
Optional Equipment
Firefighting Temperature-Sensing and Fire Extinguishing System