Product Introduction

Cold Plate Liquid Cooling in data centers uses a coolant as the medium for cooling, delivering it to the interior of each IT device.

The liquid cooling system utilizes a Manifold at the end to distribute the coolant, employing a design structure of header and collector manifolds along with the installation method of Power Distribution Units (PDUs), seamlessly integrating with server cabinets. It can be installed on the same side or both sides of the liquid-cooled server cabinet.

Product Advantages

High-Quality Materials
The main body and components such as the exhaust valve are all made of 304 stainless steel, while the hoses are made of EPDM material, ensuring the long-term safe operation of the system and resistance to corrosion.
Maintenance-Friendly
Server branch connectors all use drip-free quick connectors, which are easy to operate, plug and play, and very convenient for immediate use and removal.
Easy to Deploy
Mounted inside the cabinet using a hanging method, it can be operated by a single person, saving time and effort.
Flexible Adaptation
Flexible adaptation to a variety of servers, capable of customizing the number of branch outlets and the spacing between branch outlets according to the layout of the server in the cabinet, supporting various cabinet mounting methods.
Even Distribution
The pipeline design is rational, distributing the coolant evenly to each node and each branch flow, with an unevenness of less than 10%.
High-Quality Craftsmanship
The manifold is rinsed with deionized water, dried with hot gas, and subjected to a pressure hold at 1.5 bar of gas before being transported to the site to ensure cleanliness requirements are met.

Technical Specification

Manifold Type Main Square Tube Branch Outlet Spacing Number of Branch Outlets Branch Outlet Flow Rate(L/min) Total Inlet/Outlet Flow Rate (L/min) Maximum Pressure Tolerance
VCDU-7PN-7-01 40mm*40mm 5U 7 6 42 12bar
VCDU-8PN-8-01 40mm*40mm 8U 8 11.2 90 12bar
VCDU-9PN-9-01 40mm*40mm 4U 9 8.9 80 12bar
VCDU-9PN-9-02 40mm*40mm 4U 9 5.3 47.7 12bar
VCDU-12PN-12-01 40mm*40mm 2U/4U 12 0.9~1.1& 4.5~5.5 36 12bar
VCDU-12PN-12-02 40mm*40mm 2U/4U 12 0.9~1.1& 4.5~5.5 40 12bar
VCDU-7PN-7-01 40mm*40mm 2U/2U/4U 12 0.9~1.1& 0.9~1.1& 4.5~5.5 40 12bar
VCDU-7PN-7-01 40mm*40mm 2U 18 1.2 21.6 12bar
VCDU-7PN-7-01 40mm*40mm 2U 18 1.1 19.8 12bar

Secondary Side Prefabricated Piping

Fully Prefabricated
The pipeline adopts a prefabricated, de-engineered design, with all equipment modules prefabricated in the factory for rapid assembly at the construction site.
Safe and Reliable
Loop network design, meeting the design standards of Class A data centers, with automatic air-water separation to reduce the risk of corrosion and extend the service life of the secondary side piping.
High-End Quality
The pipeline material is hygienic-grade 304 stainless steel, effectively preventing corrosion and scaling. The sealing material is EPDM, which is compatible with a variety of secondary side coolants.
Operation and Maintenance Friendly
Optional 1-meter graded leak detection cable can be equipped with the pipeline. The leak alarm signal can be uploaded to the upper-level environmental monitoring system and platform, allowing for timely alerts upon detection of issues, facilitating operation and maintenance.
inquiry @slgdc.com